Mechanical vibration testing machine installation and operation method


Vibration test bench installation
1. First, fix the four foot bases of the table body to the places to be placed.
2, if you want to be fixed on the worktable, it is best to use angle steel to make a work table, desktop requirements level.
3, the input of the vibration table body is connected to the output hole of the control box.
1 body height 15cm vertical 2 body height 25cm horizontal
4, then control box power supply 220 / 50HZ
5. Turn on the power switch, select the waveform as full-wave, and select the vibration direction (vertical).
6, according to "two, set steps" to enter the parameter settings.
7, according to "three, frequency operation instructions" to adjust a single group or sweep frequency and other functions.
8, fine-tune AM fixed in the middle position. Press “6. Amplitude modulation control description” to adjust the amplitude.
9. Press RUN to start the vibration test.